The set up is a self-contained, water recirculating unit provided with a top tray, sump tank and a measuring tank. Drain valve and over-flow are provided on the sump tank.A centrifugal pump is fitted for water circulation, Flow control valve and bypass valve is fitted in water line to conduct the experiment at different flow rates, Flow rate of water is measured with the help of measuring tank and stop watch. Measuring tank is provided to measure the discharge. Drain valve is provided in the measuring tank to empty water in sump tank after measuring discharge. Separate level indicator and scale is provided to read the level of water in the measuring tank.